- 1-channel high accuracy thermometer for EX-areas without probe
- Inside and outside of potentially explosive areas.
- A broad variety of probes and accessories
- Measurement range -20 °C ... +80 °C
- Accuracy at +25 °C ambient temperature ±0.3 °C
- Resolution 0.1 °C
- Reference thermometer with exchangeable Pt 100 probe
- Measurement range -100 °C ... +500 °C (-148 °F ... +932 °F)
- Measurement accuracy 0.05 °C (-50 °C ... +199.99 °C) ±0.2 ° for the remaining measurement range
- Resolution 0.01 °C (-10.00 °C ... +199.99 °C) 0.1 °C for the remaining measurement range
- With fixed Pt 1000 probe.
- 60 cm or 150 cm cable
- The device has been certified together with the EB 4401 food inspection case
- Measurement range -50 °C … +200 °C
- Operating temperature -25 °C … +50 °C (handle: max. +120 °C)
- Accuracy ± 0.3 °C
- With different probe options
- Robust and impact resistant
- High accuracy
- Precise Pt 1000 probes
- Waterproof
- Accuracy ±0.3 °C
- Resolution 0.1 °C
- Sensor Pt 1000
- Operating temperature -25 °C ... +50 °C (handle: max. +120 °C)
- With fast response time
- Probe options available.
- Measurement range -50 °C ... +300 °C (-58 °F ... +572 °F)
- Accuracy ±0.5 °C (0.9 °F)
- Resolution 0.1 °C (0.2 °F)
- Measurement probe Thermocouple, type T
- High accuracy through Fuzzy logic
- Suitable for all magnetic stirrers
- Diferent Pt 100 probes available Laboratory technology
- Magnetic mixing Heating baths
- Measurement range -50 °C ... +300 °C (-58 °F ... +572 °F)
- Resolution 1 °C
- Measurement accuracy ±1 °C
- Measurement range type K -200 °C … +1,200 °C (-328 °F ... +2,192 °F)
- Measurement range type J -100 °C … +800 °C (-148 °F ... +1472 °F)
- Measurement range type T -100 °C … +300 °C (-148 °F ... +572 °F)
- Measurement range type E -100 °C … +600 °C (-148 °F ... +1,112 °F)
- Accuracy at +25 °C, type K ±0.3 °C (-99.9 °C … +250 °C)
- Accuracy at +25 °C, type J ±0.3 °C (-50 °C … +190 °C)
- Accuracy at +25 °C, type T ±0.3 °C (-50 °C … +220 °C)
- Accuracy at +25 °C, type E ±0.3 °C (-50 °C … +150 °C) ±0.5 % for the remaining measurement range
- With spare battery
- Automatic shut off after approximately 10 minutes, including needle protection
- Measurement range -50 °C ... +150 °C (-58 °F ... +302 °F)
- Resolution 0.1 °C
- Measurement accuracy ± 1 °C (-10 °C ... +120 °C),
- ± 2 °C for the remaining measurement range
- With handy housing
- Approximately 5000 hours battery lifetime
- Waterproof housing (IP65)
- Including needle protection
- Measurement range -50 °C ... +150 °C (-58 °F ... +302 °F)
- Resolution 0.1 °C (-20 °C ... + 150 °C)
- Measurement accuracy ± 1 °C (-30 °C ... +150 °C )
- With fixed probe with cable and handle
- Easy to use
- Fast measurements, high accuracy
- HACCP
- Measurement range type T -30 °C ... +199.9 °C (-22 °F ... +392 °F)
- Accuracy type T (at +25 °C) ± 0.5 °C (-30 °C ... +100 °C)
- ±1 °C for the remaining measurement range
- Resolution 0.1 °C
- Thermocouple thermometer
- Fast measurements, high accuracy
- HACCP
Measurement range type T -50 °C ... +350 °C (-58 °F ... +662 °F) - Accuracy type T (at +25 °C) ± 0.8 °C or ±0.8 %, whichever is larger
- Resolution 0.1 °C (-60 °C ... +199.9 °C) 1 °C for the remaining measurement range