- Practical in the smallest of spaces. To control pasteurization in bottles or to carry out thermal tests in small sterilizers.
- Popular with food manufacturers for testing the effects of temperature during pasteurization.
- Operating temperature -30 °C ... +150 °C (-22 °F ... +302 °F)
- Accuracy ±0.2 °C (-30 °C ... +0 °C) ±0.1 °C (0 °C … +150 °C)
- Storage temperature -20 °C ... +70 °C (-4 °F ... +158 °F)
- Max. operating pressure 20 bar (abs.)
- Flexible, bendable or rigid temperature sensors or, in addition to temperature, can also log other measurands such as pressure, humidity, conductivity.
- Operating temperature: logger -90 °C … +150 °C (-130 °F ... +302 °F)*
- Operating temperature: radio operation -30 °C … +150 °C (-22 °F ... +302 °F)
- Time accuracy < 5 sec (24 h)
- Temperature resolution 0.01 °C
- Maximum operating pressure Temperature logger 10 bar (abs), 4 bar (abs) with flexible cable probes
- Minimum operating pressure Logger with flexible cable probe 20 mbar (abs)
- Data logger versions for temperature and humidity measurements available
- With internal and external temperature probes
- Very easy to use
- Excellent price-performance ratio
- In Transport, Storage and Process monitoring.
- Resolution: Temperature 0.1 °C (0.2 °F)
- Resolution: Humidity (only humidity data loggers) 0.1 % rH
- Operating temperature -30 °C ... +70 °C (-22 °F ... +158 °F)
- Storage temperature -40 °C ... +70 °C (-40 °F ... +158 °F)
- The easy to use data loggers with USB connection monitor the temperature and/or humidity during transport and storage of sensitive goods like medicine, food, serums etc.
- Total memory capacity 40,000 measurements
- Storage temperature -40 °C ... +85 °C (- 40 °F ... +185 °F)
- Sample rate 1 min to 24 h
- Records temperatures during process monitoring and validation.
- Current measurement values and the measurement curve can be read on the multi-colored TFT display.
- Suitable for high temperature.
- Measurement range -200 °C ... +1,200 °C (-328 °F ... +2,192 °F)
- Accuracy ±0.5 °C (at +25 °C)
- Resolution 0.1 °C (0.2 °F)
- Channels 6 or 12 temperature channels
- Radio data logger system for temperature and humidity measurements
- Other measurements can be integrated using
- Modbus over IP or other protocols
- Automatic alarm when limit is exceeded
- Automatic report generation
- In monitoring of food in cooling or freezing areas, drugs and vaccine in drug stores, clinical trials in labs and in warehouses
- Resolution: temperature 0.1 °C (0.2 °F) in a range of -99.9 °C ... +199.9 °C (-147.8 °F ... +391.8 °F) 1 °C (2 °F) of the remaining measurement range
- Resolution: humidity (humidity data loggers only) 0.1 % rH
- Storage temperature -40 °C ... +85 °C (-40 °F ... +185 °F)
- Operating temperature -30 °C ... +60 °C (-22 °F ... +140 °F)